العربية العربية Português Português Français Français Русский Русский Español Español English English

Environmental Technology Park, New & High-tech Zone, Jinan City, Shandong Province, China

JINAN SHUANGYI ENVIRONMENT ENGINEERING CO., LTD.


  • Home
  • Products
  • About Us
  • Certificate
  • Contact Us
  • Fans/Air Ventilator
  • General Centrifugal Fan
  • ZHT-35 Axial Fan
  • Fire-fighting Smoke Exhaust Fan
  • Turbine Ventilator
  • Textile Axial Ventilator
  • BDW-L Roof Centrifugal Fan
  • BDW-87-4 Roof Centrifugal Ventilator
  • WBTD Type Roof Ventilator
  • SXG Type Inclined Flow Ducting Ventilator
  • SWF Type Mixed Flow Ventilator
  • GLF Air Blower Case
  • Direct Drive Wall Mount Exhaust Fan
  • Double Inlet Centrifugal Ventilator
  • High Pressure Centrifugal Ventilator
  • Inline Centrifugal Ventilator
  • Induced Draft Fan
  • High pressure centrifugal blower
  • Cooling Towers
  • DFN Cooling Tower
  • DBNL3 Normal Type Cooling Tower
  • Ultra Low Noise Cooling Tower
  • DFB Close Type Cooling Tower
  • DFH Square Shape Cross Flow Cooling Tower
  • GFNL Series Steel Frame Square Shape Counter Flow Cooling Tower
  • Industrial Cooling Tower of Reinforced Concrete Frame
  • Water Tank
  • SMC Combined Water Tank
  • Assembled Hot Dipped Galvanized Steel Water Tank
  • Stainless Steel Water Tank
  • Stainless steel round water tank
  • FRP Laboratory Facility
  • Fume Hood
  • Lab Bench
  • Reagent Shelf
  • Medical Cupboard
  • Balance Table
  • Ventilation Accessories
  • Air Vent
  • Fire Resisting Damper
  • Muffler
  • Water Chiller
  • Air Cooled(Heating) Chiller Unit
  • Water Cooled Chiller
  • LM Full Liquid Type Water Cooled Chiller Series
  • Ground Source Heat Pump Unit
  • Full-liquid Type Ground Source Heat Pump Unit
  • Variable Frequency Water Household Central Air Conditioning
  • Welcome Customized Order!
    Please Contact Us!

Muffler

Home » Products » Ventilation Accessories » Muffler
Muffler
Send Message

Description of WX-type Micro-perforated Plate Muffler:

1, WX-type micro-perforated plate muffler is a newly wideband silencer with metal structure, it is assembled by micro-perforated plate made ​​of galvanized.
Because of adopting the double micro-perforated plate perforated different rates and different rear cavity, it has a good results in a wide range of audio.

2. The muffler structure is simple work without the dust, mist afraid, water gas, and high temperature gas. It is widely used in air conditioners and ventilation ducts.

3. The muffler has the small frictional resistance when the wind speed of
9 ~ 11m / s, the pressure loss is 0.7 ~ 3mm.

WX
TX&BX
GX&FX

WX-type Micro-perforated Plate Muffler Parameter Form

Air speed(m/s)

resistance loss(Pa)

The Muffler(dB)under the following frequencies(Hz)

125

250

500

1000

2000

4000

0

0

28

29

33

30

42

51

7.5

5

25

29

33

23

32

41

10

48

23

26

29

22

30

35

14

78

19

20

24

20

26

34

22

314

10

12

19

19

27

33

25

422

3

4

14

16

25

WX Type Micro-perforated Plate Muffler Specification

Type

The size of flange(mm)

Sectional shape(mm)

The max flow rate(m3/h)

A

B

A sectional

B sectional

1

320

250

720

650

2300

2

400

250

800

650

2900

3

500

250

900

650

3600

4

630

250

1030

650

4500

5

320

320

720

720

2900

6

400

320

800

720

3700

7

500

320

900

720

4600

8

630

320

1030

720

5800

9

800

320

1200

720

7400

10

1000

320

1400

720

9200

11

400

400

800

800

7300

12

500

400

900

800

9000

13

630

400

1030

800

11500

14

800

400

1200

800

15000

15

1000

400

1400

800

18000

16

1250

400

1650

800

23000

17

500

500

900

900

11000

18

630

500

1030

900

14500

19

800

500

1200

900

18360

20

1000

500

1400

900

23000

21

1250

500

1650

900

28700

22

1600

500

2000

900

36500

23

630

630

1030

1030

18000

24

800

630

1200

1030

23600

25

1000

630

1400

1030

29500

26

1250

630

1650

1030

37000

27

1600

630

2000

1030

47000

28

800

800

1200

1200

30000

29

1000

800

1400

1200

37000

30

1250

800

1650

1200

46800

31

1600

800

2000

1200

60000

32

1000

1000

1400

1400

46800

33

1250

1000

1650

1400

58500

34

1600

1000

2000

1400

74900

Note: We can also do other specifications muffler as customer request.

Welcome to send your message to us
*Email
!!
*Content
!
Product Name
Your Name
Company
Tel/Fax.
Msn/Skype
TX-type Micro-perforated Plate Muffler Elbow

Application of TX-type Micro-perforated Plate Muffler Elbow:

TX-type micro-perforated plate muffler elbow is a novel wideband silencer with metal structure assembled by micro-perforated plate made ​​of galvanized. Because of the adopting of different micro-perforation rate and double perforated plate after different cavity, it has good effect in a wide range of audio. Our TX-based micro-perforated plate muffler elbow have two type: the monolayer micro-perforated plate muffler elbow (TX-1) and double micro-perforated plate muffler elbow (TX-2).

BX-type Flap Resistive Muffler

BX-type flap resistive muffler is a silencer of galvanized sheet structure. It is suitable for low wind speed, air-conditioned and the main channel ventilation system.


BX-type Flap Resistive Muffler Parameter Form:

Air speed(m/s)

resistance loss(Pa)

The Muffler(dB)under the following frequencies(Hz)

125

250

500

1000

2000

4000

7~8

37.2

7.0

14.0

18.0

19.5

24.0

25.5

5~6

9.8

7.0

14.3

20.0

20.7

25.5

26.3

3~4

3.9

7.5

14.5

22.0

21.7

27.0

28.0


BX-type Flap Resistive Muffler Specification Form :

Type

Specification(mm)

Flow rate(m3/h)

The No of silencer

Type

Specification(mm)

Flow rate(m3/h)

The No of silencer

A

B

A

B

1

800

500

6000

2

8

1250

1000

21000

4

2

800

630

7500

9

1600

800

21000

5

3

1000

500

9000

3

10

1600

1000

27000

4

1000

630

10000

11

1600

1250

34000

5

1000

800

13500

12

2000

1000

34000

7

6

1250

630

13500

4

13

2000

1250

43000

7

1250

800

18000

14

2000

1600

40000

GX-tube Muffler

GX-tube muffler is a silencer with resistive galvanized sheet structure. It is used for air conditioning, the end of the branch duct ventilation system and on a small amount of wind trunk duct.


GX-tube Muffler Parameter Form:

Air speed(m/s)

resistance loss(Pa)

The Muffler(dB)under the following frequencies(Hz)

125

250

500

1000

2000

4000

7~8

51

10.7

12.7

24.2

31.5

37.2

33.5

5~6

17.7

12.5

15.4

26.7

34.0

37.4

33.8

3~4

11.8

12.7

16.4

28.0

36.0

39.2

35.8

GX-tube Muffler Specification Form :

Type

Specification(mm)

Flow rate(m3/h)

The No of ducts

Type

Specification(mm)

Flow rate(m3/h)

The No of ducts

A

B

A

B

1

160

160

400

1

9

630

630

8600

4

2

200

200

700

10

800

400

6200

6

3

250

250

1200

11

800

500

8000

4

320

320

2200

12

800

630

10000

5

400

400

2900

4

13

800

800

13000

6

500

400

3800

14

1000

800

17000

9

7

500

500

5000

15

1000

1000

22000

8

630

500

6600

—

The FX Impedance Compound Muffler

The Introduction of Impedance Composite Muffler :

The impedance compound muffler is made of ultra-fine wool for sound absorption resistance. It is good for high frequency muffling effect. The role of resistance mutations within the muffler is off and the outer pipe section between the expansion chamber constituted, it is a low frequency noise and some intermediate role silencer.

Technical Performance

1. Muffler - At rated air volume, the amount of low-frequency anechoic is 10-15dB (A), IF muffler is 15-25dB (A), the amount of high-frequency anechoic is 25-30dB (A).

2. The resistance loss –At rated air volume, the average drag coefficient ε = 0.4. Losses are under different wind resistance by ΔΡ = ε × V2/2g × (mmH2O) calculations.

The notice of Installation:

1. The air speed should be adapted to control the wind through the muffler.the general wind to 6 ~ 8m / s is appropriate, if improving speed, you can choose 8 ~ 12m / s.

2. The muffler can be installed directly on the fan outlet, but it should be installed in near the location of the room, when the project is thermostatic system, muffler shell should be the same dealing as the ducts.

3. The use of temperatures should be below 100 ℃.

The FX Impedance Compound Muffler Parameter Form:

Type

Flow rate(m3/h)

Size(mm)

The diameter of flange(mm)

Note

Air speed
6m/s

Air speed
8m/s

Air speed 10m/s

Air speed 12m/s

length

Wide

Height

length

wide

1

2000

26600

3330

4000

1600

500

800

520

230

 

2

3000

4000

5000

6000

600

510

370

3

4000

5330

6670

8000

1000

700

4

5000

6660

8320

10000

800

770

400

5

6000

8000

10000

12000

900

1200

700

550

6

8000

10660

13340

16000

1000

780

630

7

10000

13320

16640

20000

1500

1000

8

15000

20000

25000

30000

1400

970

9

20000

26700

33400

40000

1800

1330

10

30000

40000

50000

60000

1800

2000

1500

1310

Home | Centrifugal Fan | Axial Fans | Cooling Towers | Water Tank | FRP Laboratory Facility | Ventilation Accessories | Water Chiller | Contact Us
  • Wendy Qi
  • Rose Wang
  • Lisa Zhang
  • Rita Gao
  • Selina Pan